Engineering consulting

Cooling system consulting, done with our own models

We answer questions about the thermal performance of cooling systems in power and process plants, HVAC, refrigeration and data centers, from the first sizing of a new system to the audit of a plant that has run for decades. Every study uses the software we develop ourselves.

Discuss your project →See a project example

Services

What we do

Eight kinds of study, for new projects and for plants in operation.

Performance audits

We find out why a cooling system delivers less than it should and what that costs in plant output. The audit includes an economic life cycle analysis.

Independent design verification

We check the thermal design of a cooling system with AEON, independently of the supplier. Recent work includes the thermal verification of a large-scale air-cooled condenser for a combined cycle power plant, on behalf of the EPC contractor.

Sizing and specification

We size cooling systems on life cycle cost, at design and off-design conditions, and draft the technical specification for your enquiry.

Wind and recirculation studies

CFD analysis shows how a system performs in wind and how much a mitigation measure recovers. We work out the payback period for each measure.

Hybridization and plume abatement

Thermal and techno-economic studies show whether converting a dry or wet system to dry/wet operation is viable, including the risk of a visible plume.

Brownfield and fuel-switch projects

We build a model of the existing cooling system and produce performance maps for its new role, for example with variable speed fans.

Product development support

Thermal and economic analyses for new products: hybrid cooling systems, customized axial flow fans, fills and heat transfer equipment.

HVAC, refrigeration and data centers

The same methods now serve equipment beyond the power plant. Recent work includes coil calculation engines for a European and a South African manufacturer of refrigeration equipment, and the thermal rating of dry coolers for a data center cooling supplier.

CFD simulation of the hot air plume from an air-cooled condenser in cross-wind, with recirculation over the fan deck and the surrounding plant buildings

In-house CFD · air-cooled condenser plume under crosswind

How we work

Two tools of our own behind every study

Standard methods treat a cooling system as one averaged unit. Our studies resolve it fan by fan and bundle by bundle.

AEON. Our thermal design software calculates every component of the system individually, at design and off-design conditions.PLUME. Our in-house CFD tool, built on OpenFOAM, has its own models for finned-tube heat exchangers and axial flow fans. Both are validated against performance characteristics measured in laboratory and wind tunnel tests.Together. The flow distribution across the fans and the air inlet temperatures calculated by PLUME go into the AEON model. The effect of wind then appears as megawatts and not only as a flow picture.

Explore AEON →

Cooling system performance optimization

A cooling system that loses a few degrees of performance costs output, fuel and fan power every operating hour. We find where performance is lost, quantify it and show which measures pay back, for air-cooled condensers, wet and hybrid cooling towers, dry coolers and air-cooled heat exchangers.

  • Performance audits: we compare measured plant data with a validated thermal model of the cooling system to find performance gaps and their root causes.
  • Wind and recirculation studies: CFD shows how wind, hot-air recirculation and surrounding buildings reduce air flow through individual fan cells, and what mitigation achieves.
  • Fan power and operating strategy: cell-by-cell models find the fan speeds and operating modes that meet the required performance with the lowest auxiliary power. They take account of effects that conventional design methods ignore, such as fan pressure recovery.
  • Digital twins: a thermal model that runs alongside the plant, fed by plant and sensor data, tracks performance continuously and quantifies improvement potential.

Hot, arid and windy sites

High ambient temperatures, wind and water scarcity are where cooling systems lose the most, and where optimization pays back fastest, in the Middle East, India and southern Africa alike. For the Ilanga 100 MWe CSP plant near Upington, South Africa, our 3D wind study showed the air-cooled condenser losing up to 24% of its air flow and heat transfer at a wind speed of 9 m/s. The result is the basis for a digital twin that quantifies the plant’s improvement potential.

Experience from large projects

Our team’s experience includes the air-cooled condenser of Medupi, one of the largest power stations in the world, and the EU Horizon 2020 project MinWaterCSP, in earlier roles at ENEXIO and Kelvion. MinWaterCSP developed hybrid dry/wet cooling and a new high-efficiency 24 ft axial fan, with the aim of cutting the cooling water consumption of solar power plants by 75–95% compared with wet cooling.

Backed by our own research

In a study financed by THERM and carried out with Stellenbosch University, we measured how much of an axial fan’s outlet energy is recovered as static pressure in forced-draft A-frame air-cooled condensers. All three fans tested showed significant recovery, with coefficients of 0.29 to 0.43. Conventional design assumes none, which can lead to oversized fan systems and unnecessary energy consumption (Journal of Physics: Conference Series, 2025).

Project example · EnBW, Altbach/Deizisau

An existing hybrid cooling tower in a new role

EnBW is replacing the coal-fired Unit 1 at Altbach/Deizisau, a 433 MWe combined heat and power plant, with a hydrogen-ready combined cycle plant that will reuse the existing dry/wet hybrid cooling tower. The supplier’s original performance curves no longer described the aged tower, and they covered only a few fixed fan speeds. We modeled the tower in AEON and delivered performance maps across fan speeds and ambient conditions. EnBW used them in its plant cycle simulations to estimate the fan power saved by variable speed drives.

0.3 °CAverage deviation of the AEON model from measured cooling water temperatures
6.1 °CAverage deviation of the original performance curves from the same measurements
665 MWeNet output of the new plant that the existing tower will serve

Published with EnBW’s engineers: Zapke, Terblanche, Breining and Abröll, “Application of thermal performance digital twins for cooling systems at fuel-switch and brownfield projects”, vgbe energy journal 7, 2024.

Experience

Engineers who have built and tested these systems

We consult in the fields we have worked in ourselves, at manufacturers, on site and in research. Albert Zapke advised the US Electric Power Research Institute on large-scale cooling systems from 2014 to 2017, and together we have published 20 journal and conference papers.

Dry cooling

Lead engineer and project engineer for the air-cooled condenser of Medupi Power Station, from supply and installation to commissioning and performance testing. Thermal rating software and CFD modeling for system suppliers and plant owners.

Wet cooling

Detailed modeling of evaporative cooling systems, including rain zone and fill configuration analyses, built on doctoral research into the rain zone performance of wet cooling towers.

Hybrid cooling

Design of a hybrid dry/wet cooling system for concentrated solar power plants in the EU-funded project MinWaterCSP, 2016 to 2018, which produced the deluge air-cooled condenser concept.

Fans

Design, testing and modeling of large axial flow fans, with research at Stellenbosch University on blade loading, vibration and fan performance. ASME Best Paper Award 2015.

CFD analysis

Cooling system analyses with our own heat exchanger and fan models in OpenFOAM, and experience with ANSYS Fluent and CFX.

Software development

Thermal rating and analysis software, written mainly in C++ and C#, with experience in Python, VBA and Fortran.

About the team →

Tell us what your
cooling system should do

Send us the question and the data you have. An engineer replies, usually within two working days.

Discuss your project →See the software