Thermal design software · Engineering consulting
Cooling systems,
solved cell by cell.
AEON calculates every fan, bundle and fill zone individually, so you see how wind, recirculation and fan switching really affect performance. For air-cooled condensers, cooling towers, coils and dry coolers.
AEON component model · three-row air-cooled condenser
Software and consulting from one engineering team
THERM develops thermal simulation software for cooling and heat transfer equipment, and uses the same tools in its consulting work. Equipment manufacturers use our models to design and select their products. Plant owners and engineers use our studies to understand and improve real installations.
Eleven technologies. Three industries.
AEON’s component-based models cover cooling and heat transfer equipment from power plants to supermarkets and data centers.
Power & process
HVAC & refrigeration
Data center cooling
AEON · Cloud platform
See what every cell is really doing
Conventional rating methods assume all cells perform the same. AEON builds your system from individual components and solves each one, including how the cells interact. Uneven airflow, hot air recirculation, wind effects, steam backflow and water maldistribution all show up in the results.
Our models, where you need them
Use THERM’s thermal models in the cloud, inside your own software, or alongside your operating plant.
AEON
Custom calculation engines
CLONE
In-house CFD · air-cooled condenser plume under crosswind
Engineering consulting
Answers for operating plants and new projects
We apply our own software, including PLUME, our in-house CFD tool with validated fan and heat exchanger models, to questions that standard methods cannot answer.
Validated against real plant data
Application of thermal performance digital twins for cooling systems at fuel-switch and brownfield projects
Real-time thermal performance monitoring of an air-cooled condenser with a digital twin
Cooling system thermal design software and consulting
THERM Development develops AEON, cloud-based thermal design and rating software for air-cooled condensers, wet and hybrid cooling towers, hot and chilled water coils, condensers, DX evaporator coils, transcritical CO2 gas coolers and data center dry coolers. Equipment manufacturers use AEON and our custom calculation engines to design and select their products.
Power plant operators, EPCs and data center engineers use our consulting studies on cooling system performance, wind effects, hot air recirculation and plume abatement. THERM works from Essen, Germany and Somerset West, South Africa, for clients worldwide.
See AEON on your
own design case
Book a demo with one of our engineers, or tell us about a cooling system question you need answered.